{"id":35072,"date":"2017-10-02T10:35:36","date_gmt":"2017-10-02T09:35:36","guid":{"rendered":"http:\/\/paginas.fe.up.pt\/~ntiec\/?p=35072"},"modified":"2018-02-09T12:55:39","modified_gmt":"2018-02-09T12:55:39","slug":"construcoes-calculo-higrotermico-ti-nspire","status":"publish","type":"post","link":"https:\/\/fe.up.pt\/ntiec\/construcoes-calculo-higrotermico-ti-nspire\/","title":{"rendered":"Constru\u00e7\u00f5es &#8211; C\u00e1lculo Higrot\u00e9rmico &#8211; TI NSpire v4.0"},"content":{"rendered":"<p><strong>M\u00e1quina de Calcular:<\/strong> TI-NSPIRE CX CAS<\/p>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"wp-image-36930 size-medium alignnone\" src=\"http:\/\/paginas.fe.up.pt\/~ntiec\/wp-content\/uploads\/2017\/10\/hg.jpg\" width=\"300\" height=\"225\" \/>\u00a0 \u00a0 \u00a0 \u00a0 \u00a0<img loading=\"lazy\" decoding=\"async\" class=\"wp-image-36932 size-medium alignnone\" src=\"http:\/\/paginas.fe.up.pt\/~ntiec\/wp-content\/uploads\/2017\/10\/tpo.jpg\" width=\"300\" height=\"225\" \/><\/p>\n<p>Programa para o <strong>c\u00e1lculo higrot\u00e9rmico<\/strong> dos par\u00e2metros\u00a0Press\u00e3o de Satura\u00e7\u00e3o (Ps), Press\u00e3o (P), Teor de Humidade (U), Temperatura Ponto de Orvalho (tpo) e Higrometria para verificar a ocorr\u00eancia de <strong>condensa\u00e7\u00f5es<\/strong> na unidade curricular de <strong>Patologia e Reabilita\u00e7\u00e3o de Edif\u00edcios (PRED)<\/strong><\/p>\n<p><strong>Vers\u00e3o 4.0<\/strong><\/p>\n<p>Comandos para correr o programa: \u00a0<strong><em>hr()<\/em><\/strong>, <em><b>tpo()<\/b>,<\/em><strong>\u00a0<em>u()<\/em><\/strong>,<strong> <em>up()<\/em><\/strong> e<strong> <em>conv()<\/em><\/strong><\/p>\n<hr \/>\n<h2><strong>DOWNLOAD<\/strong><\/h2>\n<h3><strong><a style=\"text-decoration: none;\" href=\"http:\/\/paginas.fe.up.pt\/~ntiec\/wp-content\/uploads\/2018\/02\/PRED_v4.0.zip\">PRED &#8211; C\u00e1lculo Higrot\u00e9rmico &#8211; v4.0<\/a><\/strong><\/h3>\n<p>Ap\u00f3s o download, descompactar o ficheiro .zip e transferi-lo para a m\u00e1quina atrav\u00e9s do software da Texas Instruments<\/p>\n<p>Software:\u00a0<strong><a style=\"text-decoration: none;\" title=\"Download Software da Texas Instruments\" href=\"https:\/\/education.ti.com\/pt\/portugal\/software\/update\/download-v4-master?soft=cx-cas&amp;hh=2\" target=\"_blank\" rel=\"noopener\">Download Software da Texas Instruments<\/a><\/strong><\/p>\n<h2><strong>FUN\u00c7\u00d5ES E CONTE\u00daDOS<\/strong><\/h2>\n<ul>\n<li><em>Dada a <strong>temperatura<\/strong> e a <strong>humidade relativa<\/strong>, calcula a <strong>press\u00e3o de satura\u00e7\u00e3o<\/strong> (Ps), a <strong>press\u00e3o<\/strong> (P) e o <strong>teor de humidade<\/strong> (U)\u00a0 \u2192\u00a0hr()<\/em><\/li>\n<li><em>Dada a <strong>temperatura<\/strong> e a <strong>humidade relativa<\/strong>, calcula a <strong>temperatura ponto de orvalho<\/strong>\u00a0(tpo)\u00a0 \u2192\u00a0tpo()<\/em><\/li>\n<li><em>Calcula qualquer um dos par\u00e2metros da equa\u00e7\u00e3o <strong>Ui = Ue + 0.825*[w\/(n.V)]<\/strong>\u00a0 \u2192 u()<\/em><\/li>\n<li><em>Calcula a <strong>Press\u00e3o (P)<\/strong> dado o Teor de Humidade (U)\u00a0 \u2192 up()<\/em><\/li>\n<li><em><strong>Converte\u00a0unidades<\/strong> de \u03bb e \u03c0\u00a0 \u2192 conv()<\/em><\/li>\n<\/ul>\n<hr \/>\n<h2><strong>NOVIDADES<\/strong><\/h2>\n<h5><strong><em>Vers\u00e3o 4.0<\/em><\/strong><\/h5>\n<ul>\n<li><b>Melhorias<\/b> no funcionamento do programa <b><i>conv()<\/i><\/b><\/li>\n<\/ul>\n<p><strong><em>Vers\u00e3o 3.0<\/em><\/strong><\/p>\n<ul>\n<li><em><strong>up()<\/strong><\/em> \u2192\u00a0C\u00e1lculo da <strong>Press\u00e3o (P)<\/strong> dado o Teor de Humidade (U)<\/li>\n<li><em><strong>conv()<\/strong><\/em> \u2192 Conversor de Unidades de \u03bb e \u03c0<\/li>\n<\/ul>\n<p><strong><em>Vers\u00e3o 2.0<\/em><\/strong><\/p>\n<ul>\n<li><em><strong>tpo()<\/strong><\/em> \u2192\u00a0C\u00e1lculo da Temperatura Ponto de Orvalho (tpo)<\/li>\n<li><em><strong>u()<\/strong><\/em> \u2192\u00a0C\u00e1lculo do Teor de Humidade Interno (Ui), Teor de Humidade Externo (Ue) e da Higrometria [w\/(n.V)]<\/li>\n<\/ul>\n<p><em><strong>Vers\u00e3o 1.0<\/strong><\/em><\/p>\n<ul>\n<li><em><strong>hr()<\/strong><\/em> \u2192\u00a0C\u00e1lculo da Press\u00e3o de Satura\u00e7\u00e3o (Ps), da Press\u00e3o (P) e do Teor de Humidade (U)<\/li>\n<\/ul>\n<p>&nbsp;<\/p>\n<h2><strong>CR\u00c9DITOS<\/strong><\/h2>\n<h5>NTIEC &#8211; N\u00facleo de Tecnologias de Informa\u00e7\u00e3o na Engenharia Civil<\/h5>\n<ul>\n<li><strong>Jo\u00e3o Pedro Teixeira<\/strong> (<em>ec12062@fe.up.pt<\/em>)<\/li>\n<\/ul>\n<hr \/>\n<h2><strong>IMAGENS<\/strong><\/h2>\n<h2><img loading=\"lazy\" decoding=\"async\" class=\"alignnone wp-image-2114\" src=\"http:\/\/paginas.fe.up.pt\/~ntiec\/wp-content\/uploads\/2017\/10\/u1.jpg\" alt=\"\" width=\"250\" height=\"188\" \/>\u00a0<img loading=\"lazy\" decoding=\"async\" class=\"alignnone wp-image-2108\" src=\"http:\/\/paginas.fe.up.pt\/~ntiec\/wp-content\/uploads\/2017\/10\/u2.jpg\" alt=\"\" width=\"250\" height=\"188\" \/>\u00a0<img loading=\"lazy\" decoding=\"async\" class=\"alignnone wp-image-2109\" src=\"http:\/\/paginas.fe.up.pt\/~ntiec\/wp-content\/uploads\/2017\/10\/u3.jpg\" alt=\"\" width=\"250\" height=\"188\" \/><\/h2>\n","protected":false},"excerpt":{"rendered":"<p>M\u00e1quina de Calcular: TI-NSPIRE CX CAS \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 Programa para o c\u00e1lculo higrot\u00e9rmico dos par\u00e2metros\u00a0Press\u00e3o de Satura\u00e7\u00e3o (Ps), Press\u00e3o (P), Teor de Humidade (U), Temperatura Ponto de Orvalho (tpo) e Higrometria para verificar a ocorr\u00eancia de condensa\u00e7\u00f5es na unidade curricular de Patologia e Reabilita\u00e7\u00e3o de Edif\u00edcios (PRED)&#8230;<\/p>\n","protected":false},"author":51,"featured_media":0,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[13],"tags":[],"class_list":["post-35072","post","type-post","status-publish","format-standard","hentry","category-construcoes"],"_links":{"self":[{"href":"https:\/\/fe.up.pt\/ntiec\/wp-json\/wp\/v2\/posts\/35072","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/fe.up.pt\/ntiec\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/fe.up.pt\/ntiec\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/fe.up.pt\/ntiec\/wp-json\/wp\/v2\/users\/51"}],"replies":[{"embeddable":true,"href":"https:\/\/fe.up.pt\/ntiec\/wp-json\/wp\/v2\/comments?post=35072"}],"version-history":[{"count":0,"href":"https:\/\/fe.up.pt\/ntiec\/wp-json\/wp\/v2\/posts\/35072\/revisions"}],"wp:attachment":[{"href":"https:\/\/fe.up.pt\/ntiec\/wp-json\/wp\/v2\/media?parent=35072"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/fe.up.pt\/ntiec\/wp-json\/wp\/v2\/categories?post=35072"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/fe.up.pt\/ntiec\/wp-json\/wp\/v2\/tags?post=35072"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}